SOLA-PTS: a transient, three-dimensional algorithm for fluid-thermal mixing and wall heat transfer in complex geometries
The SOLA-PTS computer code has been developed to analyze fluid-thermal mixing in the cold legs and downcomer of pressurized water reactors in support of the pressurized thermal shock study. SOLA-PTS is a transient, three-dimensional code with the capability of resolving complex geometries using variable cell noding in the three coordinate directions. The computational procedure is second-order accurate and utilizes a state-of-the-art iteration method that allows rapid convergence to an accurate solution for the pressure field. Two different turbulence models are used in the code, a two-equation k-epsilon model that is used in the cold leg pipe away from the HPI inlet and a three-equation k-epsilon-T'/sup 2/ model for use near the HPI inlet and in the downcomer. The physical modeling and the numerical procedure used in SOLA-PTS are described in this report. Applications of the method to two Creare 1/5th-scale experiments are also presented. Two appendices are included which provides a comparison of the two- and three-equation turbulence models, and instructions for setting up and running a problem with SOLA-PTS.
- Research Organization:
- Los Alamos National Lab., NM (USA)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 6544207
- Report Number(s):
- NUREG/CR-3822; LA-10132-MS; ON: TI84017113
- Country of Publication:
- United States
- Language:
- English
Similar Records
Pressurized thermal shock: TEMPEST computer code simulation of thermal mixing in the cold leg and downcomer of a pressurized water reactor. [Creare 61 and 64]
Three-dimensional calculations of transient fluid-thermal mixing in the downcomer of the Calvert Cliffs-1 plant using SOLA-PTS
Related Subjects
PWR TYPE REACTORS
THERMAL SHOCK
COMPUTER CODES
HEAT TRANSFER
HYDRAULICS
S CODES
TURBULENCE
ENERGY TRANSFER
FLUID MECHANICS
MECHANICS
REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
210200* - Power Reactors
Nonbreeding
Light-Water Moderated
Nonboiling Water Cooled