skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Effect of suture material on platelet deposition onto prosthetic material

Journal Article · · ASAIO Trans.; (United States)
OSTI ID:6515074

Previous studies have demonstrated the importance of employing prosthetic material with minimal thrombogenicity. However, the role of different suture materials in early thrombotic events on prosthetic materials has not been examined. Experiments were designed to analyze the effects of suture on platelet graft interaction using an in vivo baboon hemocompatability screen. Indium labeled, autologous platelet deposition was determined on expanded polytetrafluoroethylene (ePTFE) containing suture lines of polypropylene (Prolene), polybutester (Novafil), and ePTFE (Gore-Tex). A significant increase in platelet deposition was noted not only at the suture line, but proximal and distal to it as well. The results were different for each of the sutures employed and suggest that the suture line may influence early platelet deposition in the perianastomotic region, not only at the suture line, but proximally and distally as well.

Research Organization:
Tufts Univ. School of Medicine, Boston, MA (USA)
OSTI ID:
6515074
Journal Information:
ASAIO Trans.; (United States), Vol. 34:3
Country of Publication:
United States
Language:
English