skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Diagnostics for slapper detonator systems

Technical Report ·
DOI:https://doi.org/10.2172/6415131· OSTI ID:6415131

This report discusses diagnostics which have been used to evaluate CDU characteristics and performance, slapper characteristics and performance and the response of a HE detonator output pellet to a slapper stimulus. Many of the diagnostics discussed are appropriate for development and production testing. These include CVR current measurements, voltage probe measurements, time-of-flight measurements, threshold measurements, function time measurements, use of steel witness plates and determination of design margin. Some of the more-sophisticated, expensive diagnostics discussed have yielded very useful information, but are not required for development and production testing. 8 refs., 9 figs., 1 tab.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
6415131
Report Number(s):
UCID-21671; ON: DE89009679
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English