Application of multifuel reburn for NOx control on a 300 MWe boiler in Ukraine. Report for October 1994--December 1995
Conference
·
OSTI ID:6403645
The paper gives results of a program to design two reburn systems for operation on 300 MWe, coal-fired utility boilers operating in Ukraine. One is a natural-gas-fired system designed by ABB Combustion Engineering, installed in September 1992, and continuing to operate with a 50 percent nitrogen oxides (NOx) reduction. The paper summarizes the natural gas reburn test results. Emphasis is placed on the second demonstration, a multifuel (natural gas, oil, and/or coal) reburn system for which a conceptual design has been completed by Energy and Environmental Research Corp. Engineering drawings are being prepared by the Karkov Design Bureau in Ukraine.
- Research Organization:
- Energy and Environmental Research Corp., Irvine, CA (United States); Ladyzhin Power Station (Ukraine); Environmental Protection Agency, National Risk Management Research Lab., Research Triangle Park, NC (United States)
- Sponsoring Organization:
- USEPA; Environmental Protection Agency, Washington, DC (United States)
- OSTI ID:
- 6403645
- Report Number(s):
- PB-99-146391/XAB; CONF-9606125-; CNN: EPA-68-D2-0164
- Resource Relation:
- Conference: Air and Waste Management (AWM) annual meeting, Nashville, TN (United States), 23-28 Jun 1996
- Country of Publication:
- United States
- Language:
- English
Similar Records
Three-stage combustion (reburning) test results from a 300-MWe boiler in the Ukraine. Report for November 1988-April 1993
Evaluation of Gas Reburning & Low NOx Burners on a Wall Fired Boiler Performance and Economics Report Gas Reburning-Low NOx Burner System Cherokee Station Unit 3 Public Service Company of Colorado
Natural gas reburning for NOx control on a cyclone-fired boiler
Technical Report
·
Fri Jan 01 00:00:00 EST 1993
·
OSTI ID:6403645
+2 more
Evaluation of Gas Reburning & Low NOx Burners on a Wall Fired Boiler Performance and Economics Report Gas Reburning-Low NOx Burner System Cherokee Station Unit 3 Public Service Company of Colorado
Technical Report
·
Wed Jul 01 00:00:00 EDT 1998
·
OSTI ID:6403645
Natural gas reburning for NOx control on a cyclone-fired boiler
Technical Report
·
Tue Jan 01 00:00:00 EST 1991
·
OSTI ID:6403645
+1 more
Related Subjects
20 FOSSIL-FUELED POWER PLANTS
03 NATURAL GAS
02 PETROLEUM
01 COAL, LIGNITE, AND PEAT
AIR POLLUTION CONTROL
BURNERS
COAL
COCOMBUSTION
FOSSIL-FUEL POWER PLANTS
FUEL OILS
NATURAL GAS
NITROGEN OXIDES
STAGED COMBUSTION
UKRAINE
CARBONACEOUS MATERIALS
CHALCOGENIDES
CHEMICAL REACTIONS
COMBUSTION
CONTROL
EASTERN EUROPE
ENERGY SOURCES
EUROPE
FLUIDS
FOSSIL FUELS
FUEL GAS
FUELS
GAS FUELS
GASES
LIQUID FUELS
MATERIALS
NITROGEN COMPOUNDS
OXIDATION
OXIDES
OXYGEN COMPOUNDS
PETROLEUM PRODUCTS
POLLUTION CONTROL
POWER PLANTS
THERMAL POWER PLANTS
THERMOCHEMICAL PROCESSES
200202* - Fossil-Fueled Power Plants- Waste Management- Noxious Gas & Particulate Emissions
030700 - Natural Gas- Waste Management
020800 - Petroleum- Waste Management
010800 - Coal
Lignite
& Peat- Waste Management
03 NATURAL GAS
02 PETROLEUM
01 COAL, LIGNITE, AND PEAT
AIR POLLUTION CONTROL
BURNERS
COAL
COCOMBUSTION
FOSSIL-FUEL POWER PLANTS
FUEL OILS
NATURAL GAS
NITROGEN OXIDES
STAGED COMBUSTION
UKRAINE
CARBONACEOUS MATERIALS
CHALCOGENIDES
CHEMICAL REACTIONS
COMBUSTION
CONTROL
EASTERN EUROPE
ENERGY SOURCES
EUROPE
FLUIDS
FOSSIL FUELS
FUEL GAS
FUELS
GAS FUELS
GASES
LIQUID FUELS
MATERIALS
NITROGEN COMPOUNDS
OXIDATION
OXIDES
OXYGEN COMPOUNDS
PETROLEUM PRODUCTS
POLLUTION CONTROL
POWER PLANTS
THERMAL POWER PLANTS
THERMOCHEMICAL PROCESSES
200202* - Fossil-Fueled Power Plants- Waste Management- Noxious Gas & Particulate Emissions
030700 - Natural Gas- Waste Management
020800 - Petroleum- Waste Management
010800 - Coal
Lignite
& Peat- Waste Management