Evaluation of pilot-scale pollution control devices for hazardous-waste incineration
Abstract
The paper summarizes the results of emission tests carried out on three pilot-scale air pollution-control devices. The units were connected to a slip stream from the ENSCO, Inc. hazardous-waste incinerator at El Dorado, Arkansas. The three units were a Hydro Sonic System wet scrubber; an ETS dry scrubber; and a Vulcan Engineering Company high temperature baghouse. The units were evaluated for their capability in removing particulate matter and HCl. Full discussion of the testing program and results is in an EPA report, Evaluation of Air Pollution Control Devices for Hazardous Waste Combustion, now undergoing final review in the Agency.
- Authors:
- Publication Date:
- Research Org.:
- Environmental Protection Agency, Cincinnati, OH (USA). Hazardous Waste Engineering Research Lab.
- OSTI Identifier:
- 6394209
- Report Number(s):
- PB-86-102654/XAB
- Resource Type:
- Technical Report
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 54 ENVIRONMENTAL SCIENCES; AIR POLLUTION CONTROL; POLLUTION CONTROL EQUIPMENT; HAZARDOUS MATERIALS; COMBUSTION PRODUCTS; INCINERATORS; PILOT PLANTS; BAGHOUSES; PARTICLES; SCRUBBERS; CONTROL; EQUIPMENT; FUNCTIONAL MODELS; MATERIALS; POLLUTION CONTROL; 500200* - Environment, Atmospheric- Chemicals Monitoring & Transport- (-1989)
Citation Formats
Freeman, H M, and Olexsey, R A. Evaluation of pilot-scale pollution control devices for hazardous-waste incineration. United States: N. p., 1985.
Web.
Freeman, H M, & Olexsey, R A. Evaluation of pilot-scale pollution control devices for hazardous-waste incineration. United States.
Freeman, H M, and Olexsey, R A. 1985.
"Evaluation of pilot-scale pollution control devices for hazardous-waste incineration". United States.
@article{osti_6394209,
title = {Evaluation of pilot-scale pollution control devices for hazardous-waste incineration},
author = {Freeman, H M and Olexsey, R A},
abstractNote = {The paper summarizes the results of emission tests carried out on three pilot-scale air pollution-control devices. The units were connected to a slip stream from the ENSCO, Inc. hazardous-waste incinerator at El Dorado, Arkansas. The three units were a Hydro Sonic System wet scrubber; an ETS dry scrubber; and a Vulcan Engineering Company high temperature baghouse. The units were evaluated for their capability in removing particulate matter and HCl. Full discussion of the testing program and results is in an EPA report, Evaluation of Air Pollution Control Devices for Hazardous Waste Combustion, now undergoing final review in the Agency.},
doi = {},
url = {https://www.osti.gov/biblio/6394209},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun Sep 01 00:00:00 EDT 1985},
month = {Sun Sep 01 00:00:00 EDT 1985}
}
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.