skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Influence of electrostatic charge on the performance of 10 mm nylon cyclones

Journal Article · · Am. Ind. Hyg. Assoc. J.; (United States)

The 10 mm nylon cyclone is commonly used for measuring the respirable aerosol concentration of airborne dust. Under some conditions the measured concentration may be lower than the actual value due to electrostatic charge. The use of a cyclone moulded from conducting, graphite-filled nylon is proposed. Tests of such a cyclone are reported. The results showed a consistency, providing a more accurate representation of deposition in the human respiratory tract.

OSTI ID:
6377441
Journal Information:
Am. Ind. Hyg. Assoc. J.; (United States), Vol. 45:7
Country of Publication:
United States
Language:
English