Title: US progress on the development of CR-39 based neutron dosimeters

Conference ·
OSTI ID:6273759

Historically at US nuclear facilities, two types of personnel neutron dosimeters have been in routine use: nuclear track emulsion-Type A (NTA) film and thermoluminescent dosimeter (TLD)-albedo. Both of these dosimeters have energy-dependent responses. Therefore, the neutron energy spectra must be known, to interpret the dosimeter results properly. A new state-of-the-art dosimetry system has been developed within the US Department of Energy (US DOE) Personnel Neutron Dosimeter Evaluation and Upgrade Program. This system is called the combination thermoluminescent dosimeter/track etch dosimeter (TLD/TED). This paper briefly describes US DOE research currently being conducted to further enhance the TED portion of the combination TLD/TED system. The research areas involved include dose sensitivity, neutron energy range, specialized radiators, self-developing dosimeters, and neutron spectrometry. 1 fig., 1 tab.

Research Organization:
Pacific Northwest Lab., Richland, WA (USA)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
6273759
Report Number(s):
PNL-SA-14764; CONF-870525-2; ON: DE87012161; TRN: 87-030769
Resource Relation:
Conference: Workshop on development of personnel neutron dosimeters based on track etch detectors, Harwell, UK, 12 May 1987; Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English