skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A comparison of experiment, CEPXS/ONETRAN, TIGERP, and QUICKE2 net electron emission coefficients for various bremsstrahlung spectra

Conference ·
OSTI ID:6224757

This work compares a carefully designed experiment with the predictions of four different codes (CEPXS/ONETRAN, TIGERP, TIGER and QUICKE2) for the complex bremsstrahlung spectra typical of very intense pulsed power x-ray generators. Accurate calculation of net photon-induced electron emission yields at material interfaces using Monte Carlo codes can be particularly difficult if the forward and reverse partial yields are of similar magnitudes. In such a circumstance, the statistical error in the Monte Carlo solution (TIGER or TIGERP) must be kept to a minimum to accurately resolve the difference. CEPXS/ONETRAN is a new deterministic coupled electron/photon transport code that is faster than Monte Carlo and is not subject to statistical error. QUICKE2 evaluates an analytical approximation and is also much less expensive to run than the Monte Carlo codes. The comparison of net yields is a sensitive test of the relative accuracy and efficiency of these various codes. We find that all of the codes except QUICKE2 substantially agree with the experiments for the forward net yields. Howver, for reverse net yields from high-Z materials, all the codes overpredict relative to measurements.

Research Organization:
Sandia National Labs., Albuquerque, NM (USA); Mission Research Corp., San Diego, CA (USA)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
6224757
Report Number(s):
SAND-87-0292C; CONF-870724-16; ON: DE87012370; TRN: 87-031689
Resource Relation:
Conference: 24. annual conference on nuclear and space radiation in electronics, Snowmass, CO, USA, 28 Jul 1987; Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English