Fuzzy logic controllers for electric motors and wind turbines. Report for October 1996-April 1997
Technical Report
·
OSTI ID:620590
The paper discusses a precision laboratory test facility that has been assempbled to test the performance of two fuzzy-logic based controllers for electric motors and wind turbines. Commercial induction motors up to 10 hp (7.46 kWe) in motors and equipped with adjustable-speed drives (ASDs) were used to test the motor optimizers.
- Research Organization:
- Environmental Protection Agency, Research Triangle Park, NC (United States)
- OSTI ID:
- 620590
- Report Number(s):
- PB-98-140338/XAB; EPA-600/A-98/013; TRN: 81592013
- Resource Relation:
- Other Information: PBD: Apr 1997
- Country of Publication:
- United States
- Language:
- English
Similar Records
Improving ac motor efficiency with fuzzy logic energy optimizer
Fuzzy logic motor control for pollution prevention and improved energy efficiency. Report for October 1992-August 1993
Fuzzy-logic control of AC induction motors
Technical Report
·
Mon Aug 01 00:00:00 EDT 1994
·
OSTI ID:620590
Fuzzy logic motor control for pollution prevention and improved energy efficiency. Report for October 1992-August 1993
Technical Report
·
Fri Oct 01 00:00:00 EDT 1993
·
OSTI ID:620590
+2 more
Fuzzy-logic control of AC induction motors
Technical Report
·
Wed Jan 01 00:00:00 EST 1992
·
OSTI ID:620590
+2 more