This report presents a method to estimate specific plant FGD retrofit costs. The basis of the estimate is a new plant's FGD system cost, as provided in EPRI's Economic Evaluation of FGD Systems CS-3342, or any other generalized cost estimate. The methodology adjusts the capital cost for the sulfur content of the coal, sulfur removal required, unit size, geographic location variables, and retrofit considerations. The methodology also allows the user to calculate first year operating and maintenance (O and M) costs based on site-specific variables. Finally, the report provides a means to adjust for remaining unit life in determining the levelized busbar cost. Levelized cost is presented in mills/kWh and $/t SO/sub 2/ removed.