Title: PBF LOCA test LOC-6 fuel-behavior report. [PWR]

Technical Report ·
OSTI ID:6137957

This report presents the results of Loss-of-Coolant (LOC) Test LOC-6, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory by EG and G Idaho, Inc., for the US Nuclear Regulatory Commission. Postirradiation examination results are included, together with the results of thermal-hydraulic and fuel behavior calculations using the RELAP4 and FRAP-T6/BALON-2 computer codes. Two of the four light water reactor type fuel rods ballooned and ruptured during the test. Peak cladding temperatures at the rupture locations were high in the alpha phase (1066 and 1098/sup 0/K). The effects of initial rod internal prepressurization and prior irradiation were investigated during the experiment. The effect of rod prepressurization was found to be significant, and, for burnups of about 17,000 MWd/t, prior irradiation increased cladding circumferential strains at failure.

Research Organization:
EG and G Idaho, Inc., Idaho Falls (USA)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
6137957
Report Number(s):
NUREG/CR-3184; EGG-2244; ON: DE83012115
Resource Relation:
Other Information: Includes 9 sheets of 48 and 24x reduction microfiche
Country of Publication:
United States
Language:
English