Raccoon Mountain pumped-storage plant: Ten years operating experience
Journal Article
·
· IEEE Trans. Power Electronics; (United States)
Operational experience at the 1 530 MW Raccoon Mountain underground pumped-storage plant can be relevant to other large hydro facilities. A number of unusual features were incorporated and individual unit size was only recently overtaken elsewhere. Direct water cooling of rotor and stator winding has been successfully applied to salient pole machines. A number of problems, including difficulties with oil-filled 161 kV current transformers, and some mechanical aspects, are reported. Designed for remote supervisory control, the plant has required closer attention. Operating statistics are included.
- Research Organization:
- Tennessee Valley Authority, Chattanooga, TN
- OSTI ID:
- 6050279
- Journal Information:
- IEEE Trans. Power Electronics; (United States), Vol. EC-2:3
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effects of operation of Raccoon Mountain pumped-storage project on Nickajack Reservoir flow conditions
Comparison of acoustic and conventional flow measurement techniques at the Raccoon Mountain Pumped-Storage Plant: Final report
Results from transient tests and spherical valve closure tests, Raccoon Mountain Pumped-Storage Plant
Technical Report
·
Tue Jan 01 00:00:00 EST 1980
·
OSTI ID:6050279
Comparison of acoustic and conventional flow measurement techniques at the Raccoon Mountain Pumped-Storage Plant: Final report
Technical Report
·
Sat Aug 01 00:00:00 EDT 1987
·
OSTI ID:6050279
+1 more
Results from transient tests and spherical valve closure tests, Raccoon Mountain Pumped-Storage Plant
Technical Report
·
Sat Sep 01 00:00:00 EDT 1984
·
OSTI ID:6050279
Related Subjects
13 HYDRO ENERGY
PUMPED STORAGE POWER PLANTS
PERFORMANCE
COOLING SYSTEMS
FAILURE MODE ANALYSIS
INSULATING OILS
MECHANICS
OPERATION
POWER RANGE 100-1000 MW
REMOTE CONTROL
REVIEWS
ROTORS
STATISTICS
STATORS
TRANSFORMERS
CONTROL
DOCUMENT TYPES
ELECTRICAL EQUIPMENT
ENERGY SYSTEMS
EQUIPMENT
HYDROELECTRIC POWER PLANTS
MATHEMATICS
OILS
ORGANIC COMPOUNDS
OTHER ORGANIC COMPOUNDS
PEAKING POWER PLANTS
POWER PLANTS
SYSTEM FAILURE ANALYSIS
SYSTEMS ANALYSIS
130300* - Hydro Energy- Plant Design & Operation
130700 - Hydro Energy- Power-Conversion Systems
PUMPED STORAGE POWER PLANTS
PERFORMANCE
COOLING SYSTEMS
FAILURE MODE ANALYSIS
INSULATING OILS
MECHANICS
OPERATION
POWER RANGE 100-1000 MW
REMOTE CONTROL
REVIEWS
ROTORS
STATISTICS
STATORS
TRANSFORMERS
CONTROL
DOCUMENT TYPES
ELECTRICAL EQUIPMENT
ENERGY SYSTEMS
EQUIPMENT
HYDROELECTRIC POWER PLANTS
MATHEMATICS
OILS
ORGANIC COMPOUNDS
OTHER ORGANIC COMPOUNDS
PEAKING POWER PLANTS
POWER PLANTS
SYSTEM FAILURE ANALYSIS
SYSTEMS ANALYSIS
130300* - Hydro Energy- Plant Design & Operation
130700 - Hydro Energy- Power-Conversion Systems