skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Development of burner flame diagnostic system for utility boilers

Conference ·
OSTI ID:6011301
 [1]; ;  [2]; ; ;  [3]
  1. Engineering Development Center, Tokyo Electric Power Co., Tokyo (JP)
  2. Engineering Research Center, Tokyo Electric Power Co., Tokyo (JP)
  3. Boiler Plant Div., Ishikawajima-Harima Heavy Industries Co., Ltd., Tokyo (JP)

The combustion monitoring system in utility boilers generally consists of equipment for analyzing O{sub 2}, NO{sub x} and dust in flue gas at the boiler exit. The burner flame diagnostic system developed in this research is comprised of optical probes, optical fibers connecting the burners to a multispectrometer through an optical scanner for multiple burners of the boiler and computer for evaluating flame behavior, so as to serve precise spectroscopic analysis. This research began with a small size test furnace in order to derive combustion evaluation indices, thus successfully leading to theoretical expression in application to a large scale utility boiler. A ploto-type system was mounted on a 350 MW boiler with test result that clearly demonstrate this system to be effective for precise evaluation of individual burners of the boiler.

OSTI ID:
6011301
Report Number(s):
CONF-901034-
Resource Relation:
Conference: ASME/IEEE joint power generation conference, Boston, MA (USA), 21-25 Oct 1990; Other Information: Technical Paper 90-JPGC/Pwr-3
Country of Publication:
United States
Language:
English