Title: Design and testing of a cavity-type, steam-generating, central receiver for a solar thermal power plant

Journal Article · · J. Eng. Power; (United States)
DOI:https://doi.org/10.1115/1.3230282· OSTI ID:5922638
 [1];  [2]
  1. Foster Wheeler Development Corp., Livingston, NJ
  2. Martin Marietta Aerospace, Denver, CO

This paper focuses on the design and operating aspects of a 10-MWe cavity-type, natural-circulation, steam-generating receiver for a central-receiver thermal power plant. The development of the receiver concept and the basic design features are described. The solar energy input analysis, thermal/hydraulic performance, and structural design of the receiver are discussed along with its control concept and transient operation. The design, construction, and testing of a 5-MWt scaled-down version of the 10-MWe receiver are summarized with emphasis on test objectives, scaling criteria, and design similarities to the full-scale receiver.

OSTI ID:
5922638
Journal Information:
J. Eng. Power; (United States), Vol. 102
Country of Publication:
United States
Language:
English