skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Development of a dose algorithm for the modified panasonic UD-802 personal dosimeter used at three mile island

Conference · · Trans. Am. Nucl. Soc.; (United States)
OSTI ID:5897455

During the fall of 1981, the personnel dosimetry group at GPU Nuclear Corporation at Three Mile Island (TMI) requested assistance from The University of Michigan (UM) in developing a dose algorithm for use at TMI-2. The dose algorithm had to satisfy the specific needs of TMI-2, particularly the need to distinguish beta-particle emitters of different energies, as well as having the capability of satisfying the requirements of the American National Standards Institute (ANSI) N13.11-1983 standard. A standard Panasonic UD-802 dosimeter was modified by having the plastic filter over element 2 removed. The dosimeter and hanger consists of the elements with a 14 mg/cm/sup 2/ density thickness and the filtrations shown. The hanger on this dosimeter had a double open window to facilitate monitoring for low-energy beta particles. The dose algorithm was written to satisfy the requirements of the ANSI N13.11-1983 standard, to include /sup 204/Tl with mixtures of /sup 204/Tl with /sup 90/Sr//sup 90/Y and /sup 137/Cs, and to include 81- and 200-keV average energy X-ray spectra. Stress tests were conducted to observe the algorithm performance to low doses, temperature, humidity, and the residual response following high-dose irradiations. The ability of the algorithm to determine dose from the beta particles of /sup 147/Pm was also investigated.

Research Organization:
Univ. of Michigan, Ann Arbor (USA)
OSTI ID:
5897455
Report Number(s):
CONF-881011-
Journal Information:
Trans. Am. Nucl. Soc.; (United States), Vol. 57; Conference: Joint meeting of the European Nuclear Society and the American Nuclear Society, Washington, DC, USA, 30 Oct - 4 Nov 1988
Country of Publication:
United States
Language:
English

Similar Records

Neutron dosimetry in containment of a pressurized water reactor utilizing the Panasonic UD-802 dosimetry system
Technical Report · Sun Jan 01 00:00:00 EST 1984 · OSTI ID:5897455

Two methods for examining angular response of personnel dosimeters
Journal Article · Wed Jun 01 00:00:00 EDT 1988 · Health Phys.; (United States) · OSTI ID:5897455

Performance comparisons of selected personnel-dosimetry systems in use at Department of Energy facilities
Technical Report · Sat Oct 01 00:00:00 EDT 1983 · OSTI ID:5897455