Designing for post-accident radiological conditions
Technical Report
·
OSTI ID:5832525
Nuclear power plant design efforts have previously tacitly assumed that in the event of an accident, all actions necessary to bring the plant to a cold shutdown could be accomplished from a well-protected control room. However, the incident at Three Mile Island, Unit 2 (TMI-2), showed that access to the balance-of-plant is desirable, and perhaps even necessary, to determine the past and future course of an accident and its consequences. The present report reviews the in-plant radiological consequences of the TMI-2 accident and formulates radiation protection design criteria for the balance-of-plant which would minimize post-accident in-plant radiation exposure.
- Research Organization:
- Sargent and Lundy, Chicago, IL (USA)
- OSTI ID:
- 5832525
- Report Number(s):
- EPRI-NSAC-17; ON: DE82901459; TRN: 82-000571
- Country of Publication:
- United States
- Language:
- English
Similar Records
The Nuclear Accident at Three Mile Island a Practical Lesson in the Fundamental Importance of Effective Communications
Management of Ultimate Risk of Nuclear Power Plants by Source Terms - Lessons Learned from the Chernobyl Accident
TMI-2 (Three Mile Island Unit 2): The early radiological conditions of the reactor building
Conference
·
Tue Jul 01 00:00:00 EDT 2008
·
OSTI ID:5832525
Management of Ultimate Risk of Nuclear Power Plants by Source Terms - Lessons Learned from the Chernobyl Accident
Conference
·
Sat Jul 01 00:00:00 EDT 2006
·
OSTI ID:5832525
TMI-2 (Three Mile Island Unit 2): The early radiological conditions of the reactor building
Conference
·
Fri Jan 01 00:00:00 EST 1988
· Trans. Am. Nucl. Soc.; (United States)
·
OSTI ID:5832525
Related Subjects
22 GENERAL STUDIES OF NUCLEAR REACTORS
NUCLEAR POWER PLANTS
REACTOR ACCIDENTS
RADIATION PROTECTION
RADIATION MONITORS
THREE MILE ISLAND-2 REACTOR
ACCIDENTS
ENRICHED URANIUM REACTORS
MEASURING INSTRUMENTS
MONITORS
NUCLEAR FACILITIES
POWER PLANTS
POWER REACTORS
PWR TYPE REACTORS
REACTORS
THERMAL POWER PLANTS
THERMAL REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
220900* - Nuclear Reactor Technology- Reactor Safety
NUCLEAR POWER PLANTS
REACTOR ACCIDENTS
RADIATION PROTECTION
RADIATION MONITORS
THREE MILE ISLAND-2 REACTOR
ACCIDENTS
ENRICHED URANIUM REACTORS
MEASURING INSTRUMENTS
MONITORS
NUCLEAR FACILITIES
POWER PLANTS
POWER REACTORS
PWR TYPE REACTORS
REACTORS
THERMAL POWER PLANTS
THERMAL REACTORS
WATER COOLED REACTORS
WATER MODERATED REACTORS
220900* - Nuclear Reactor Technology- Reactor Safety