OSTI ID:5779739

This paper discusses program objectives, approaches, current status and results, future activities, and schedules for EPA's program for research and development, field evaluation, and demonstration of Limestone Injection Multistage Burner (LIMB) technology. Primary emphasis is on: (1) the full-scale demonstration being conducted on Ohio Edison's 104-MW wall-fired Edgewater Station Unit 4; (2) evaluation on a 50 million Btu/hr tangentially fired prototype nearing completion; (3) on-going field evaluation on Richmond Power and Light's 61-MW tangentially fired Whitewater Valley Generating Station Unit 2. The new program for demonstration on Virginia Electric Power's 180-MW tangentially fired Yorktown II Plant is also described. The LIMB process is based on injecting dry sorbents into the boiler for direct capture of SO/sub 2/ from the combustion gases. LIMB combines sorbent injection for SO/sub 2/ control with the use of low-NOx burners, in which staged combustion is utilized for NOx control.

Research Organization:
Environmental Protection Agency, Research Triangle Park, NC (USA). Air and Energy Engineering Research Lab.
OSTI ID:
5779739
Report Number(s):
PB-88-103031/XAB; EPA-600/D-87/267
Country of Publication:
United States
Language:
English