This volume deals with the details of how thermionic conversion works, and how it is used in a coal-fired furnace to achieve power plant efficiencies of 45%, and overall costs of 36.3 mills/kWh. A review of the fundamental technical aspects of thermionic conversion is given. The overall Thermionic Heat Exchanger (THX) design, the heat pipe design, and the interaction of the heat pipes with the furnace are presented. Also, the operational characteristics of thermionic converters are described. Details on the computer program used to perform the parametric study are given. The overall program flow is reviewed along with the specifics of how the THX subroutine designed the converter to match the conditions imposed. Also, input costs and variables effecting the THX's performance are detailed. The efficiencies of the various power plants studied are given as a function of the air preheat temperature, size of the power plant, and thermionic level of performance.

Research Organization:
Rasor Associates, Inc., Sunnyvale, CA (USA)
DOE Contract Number:
AC02-76ET11293
OSTI ID:
5777458
Report Number(s):
DOE/ET/11293-T5-Vol.4; NSR-2-19-Vol.4; COO-2263-19-Vol.4; ON: DE82000735
Country of Publication:
United States
Language:
English