Title: Safety analysis results for cryostat ingress accidents in ITER

Journal Article · · Journal of Fusion Energy
; ;  [1]
  1. Idaho National Engineering Lab., ID (United States)

Accidents involving the ingress of air, helium, or water into the cryostat of the International Thermonuclear Experimental Reactor (ITER) tokamak design have been analyzed with a modified version of the MELCOR code for the ITER Non-site Specific Safety Report (NSSR-1). The air ingress accident is the result of a postulated breach of the cryostat boundary into an adjoining room. MELCOR results for this accident demonstrate that the condensed air mass and increased heat loads are not a magnet safety concern, but that the partial vacuum in the adjoining room must be accommodated in the building design. The water ingress accident is the result of a postulated magnet arc that results in melting of a Primary Heat Transport System (PHTS) coolant pipe, discharging PHTS water and PHTS water activated corrosion products and HTO into the cryostat. MELCOR results for this accident demonstrate that the condensed water mass and increased heat loads are not a magnet safety concern, that the cryostat pressure remains below design limits, and that the corrosion product and HTO releases are well within the ITER release limits. 6 refs., 2 figs., 1 tab.

OSTI ID:
577082
Journal Information:
Journal of Fusion Energy, Vol. 16, Issue 1-2; Other Information: PBD: Jun 1997
Country of Publication:
United States
Language:
English