Title: Detection of OH in a flame by degenerate four-wave mixing

Journal Article · · Opt. Lett.; (United States)
DOI:https://doi.org/10.1364/OL.11.000279· OSTI ID:5721306

The detection of OH in a laminar premixed air-methane flame by degenerate four-wave mixing (DFWM) is reported. The four-wave mixing spectrum was recorded in the region of the R/sub 1/, R/sub 2/ band heads of the (0, 0) /sup 2/..sigma..-/sup 2/Pi transition, showing clearly resolved rotational structure. Applications of the DFWM technique to combustion diagnostics are discussed. As an example, the distribution of sodium atoms in a sodium-seeded flame has been measured using a 90/sup 0/ geometry to enhance spatial resolution.

Research Organization:
Clarendon Laboratory, University of Oxford, Parks Road, Oxford OX1 3PU UK
OSTI ID:
5721306
Journal Information:
Opt. Lett.; (United States), Vol. 11:5
Country of Publication:
United States
Language:
English