Title: ARC/SPAR sealing system - Preliminary field evaluation

Conference · · Nucl. Mater. Manage. Annu. Meet. Proc.; (United States)
OSTI ID:5697402

The ARC/SPAR sealing system, based on an ultra-sonic signature and designed for sealing CANDU-type spent fuel, has been undergoing field evaluation at Gentilly-2 600 MW Reactor for the last ten months. The test was designed to evaluate the hardware and software of the system, the effort required for the application and verification of the containment and seals, the interference with operator, the procedures and the false- and missed alarm rates. Routine use conditions were emphasized throughout the test. In the course of the trial the entire content of the spent fuel in the pond was sealed. Preliminary results indicate that the system is acceptable. Hardware, software and procedures except for the transducer worked well. Transducer failure occurred too frequently at an unacceptable rate. The problem was identified and will hopefully be overcome. Level of intrusion with operations could be considered acceptable. Inspectors carrying out seal application and verification were adequately trained and performed satisfactorily. Auto- and crosscorrelations are reported. Recommendations are made for the improvement of equipment and procedures. The test will continue until the end of this year.

Research Organization:
AECB
OSTI ID:
5697402
Report Number(s):
CONF-870713-; TRN: 88-002539
Journal Information:
Nucl. Mater. Manage. Annu. Meet. Proc.; (United States), Vol. 16; Conference: 28. INMM annual meeting on safeguards: a mature technology, Newport Beach, CA, USA, 12 Jul 1987
Country of Publication:
United States
Language:
English