skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Capillary column gas chromatography, resonance enhanced multiphoton ionization, time-of-flight mass spectrometry laser-induced fluorescence, flame ionization detection system for the determination of polynuclear aromatic compounds in complex mixtures

Technical Report ·
OSTI ID:5630420

Of the thousands of chemical compounds that have been deemed mutagenic or carcinogenic, it is generally agreed that the polynuclear aromatic hydrocarbons (PAC) are among the most potent. Because of the wide range of potency of PAC, even among geometric isomers and substitutional derivatives, it is important to fully characterize these samples. This task is a formidable one, usually requiring elaborate sample clean-up and fractionation prior to analysis. A multidimensional, laser-based analytical instrument has been developed that, when utilized to the full extent of its capabilities, could be the solution to this complex analytical problem. The overall technique is termed Capillary Column Gas Chromatography, Resonance Enhanced Multiphoton Ionization, Time-Of-Flight Mass Spectrometry, Laser-induced Fluorescence, with parallel Flame Ionization Detection (CC/GC-REMPI-TOF/MS-LIF-FID). This system combines the selectivity and sensitivity of two complementary laser-based methods, REMPI and LIF, with an extremely powerful and proven analytical tool, GC/MS. The GC effluent passes through the ion source of a TOF/MS, where it is interrogated by a tunable ultraviolet laser beam. All laser-analyte interaction products (cations, electrons, and photons) are simultaneously monitored utilizing the TOF/MS, a total electron current detector (TECD), and a LIF detector. The simultaneous availability of this information simplifies the characterization task. The present absolute detection limits for several PAC have been determined to be in the low picogram range. Also, a linear dynamic range of approximately four orders of magnitude has been established for the TECD, indicating that this technique is both sensitive and quantitative. Further, the use of deuterated analogs, of selected PAC, as internal reference standards greatly assists in quantitation. 219 refs., 37 figs., 13 tabs.

Research Organization:
Ames Lab., IA (USA)
DOE Contract Number:
W-7405-ENG-82
OSTI ID:
5630420
Report Number(s):
IS-T-1262; ON: DE86012676
Resource Relation:
Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English