skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Effect of recirculation pump trip following anticipated transients without scram at Big Rock Point

Technical Report ·
OSTI ID:5630389

As requested by the US Atomic Energy Commission (now US Nuclear Regulatory Commission) in their Technical Report on Anticipated Transients Without Scram (ATWS) for Water-Cooled Reactors (WASH-1270), Consumers Power Company has submitted analyses which describe the response of their Big Rock Point (BRP) Plant to ATWS. The original analyses were submitted on Febuary 21, 1975, and results indicated that a recirculation pump trip (RPT) was effective in limiting the consequences of an ATWS. The response of BRP to an ATWS was reanalyzed as a part of the Big Rock Point Probabilistic Risk Assessment (PRA). Results of the analysis were submitted on February 26, 1981, with the conclusion that automatic RPT provides little safety improvement at BRP. Purpose of this report is to evaluate the submitted analyses to determine the effectiveness of Recirculation Pump Trip in ATWS recovery.

Research Organization:
EG and G Idaho, Inc., Idaho Falls (USA)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
5630389
Report Number(s):
EGG-EA-5533; ON: TI85014383
Country of Publication:
United States
Language:
English