ECE diagnostic for the TARA tandem mirror machine using a fast-scanning Michelson interferometer
This ECE (electron cyclotron emission) diagnostic utilizes a fast-scanning Michelson interferometer to determine two parameters, the temperature and the loss cone angle, of the distribution function of the hot electrons (T-italicapprox. >100 keV) generated in the axisymmetric plug plasma of the TARA tandem mirror device. The radiation transport system employs a lens relay and a low-pass grating filter in order to transmit the synchrotron radiation over a spectral range of 2.9--18.6 cm/sup -1/. This enables us to study the emitted radiation spectrum up to the 40th harmonic of the electron--cyclotron frequency in the plug plasma (B-italic = 5 kG). Details of the design principles and the development of the diagnostic at TARA will be presented.
- Research Organization:
- Laboratory for Plasma and Fusion Energy Studies, University of Maryland, College Park, Maryland 20742
- OSTI ID:
- 5565271
- Journal Information:
- Rev. Sci. Instrum.; (United States), Vol. 57:8
- Country of Publication:
- United States
- Language:
- English
Similar Records
Status of the design of the ITER ECE diagnostic
Gas pressure measurements and control in the Tara tandem mirror experiment
Related Subjects
MICHELSON INTERFEROMETER
DESIGN
FABRICATION
PLASMA DIAGNOSTICS
TARA DEVICES
CHARGED-PARTICLE TRANSPORT
DISTRIBUTION FUNCTIONS
ELECTRON DENSITY
LOSS CONE
PLUGGING
SYNCHROTRON RADIATION
BREMSSTRAHLUNG
ELECTROMAGNETIC RADIATION
FUNCTIONS
INTERFEROMETERS
MAGNETIC MIRRORS
MEASURING INSTRUMENTS
OPEN PLASMA DEVICES
RADIATION TRANSPORT
RADIATIONS
TANDEM MIRRORS
THERMONUCLEAR DEVICES
700102* - Fusion Energy- Plasma Research- Diagnostics