Leakage rates of an innovative hypersonic engine seal were measured using a specially developed static high temperature seal test fixture at NASA Lewis Research Center. The three foot long structural panel-edge seal is designed to minimize leakage of high temperature, high pressure gases past the movable panels of advanced ramjet/scramjet engines. The seal is made of a stack of precision machined ceramic wafer pieces that are inserted into a closely conforming seal channel in the movable engine panel. The wafer seal accommodates the significant distortions in the adjacent engine walls through relative sliding between adjacent wafers. Seal leakage rates are presented for engine simulated air temperatures up to 1350F and for engine pressures up to 100 psi. Leakage rates are also presented for the seal, sealing both a flat wall condition, and an engine simulated distorted wall condition in which the distortion was 0.15 in. in only an 18 in. span. Seal leakage rates were low, meeting an industry-established tentative leakage limit for all combinations of temperature, pressure, and wall conditions considered. Comparisons are made between the measured leakage rates and leakage rates predicted using a seal leakage model developed from externally-pressurized gas film bearing theory.

Research Organization:
National Aeronautics and Space Administration, Cleveland, OH (United States). Lewis Research Center
OSTI ID:
5515812
Report Number(s):
N-91-22567; NASA-TM-103737; E-5942; NAS-1.15:103737
Country of Publication:
United States
Language:
English