skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Multiloop integral system test (MIST): Test Group 36, Pump operation

Technical Report ·
DOI:https://doi.org/10.2172/5492059· OSTI ID:5492059
 [1]
  1. Babcock and Wilcox Co., Lynchburg, VA (USA). Nuclear Power Div.

The multiloop integral system test (MIST) was part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock Wilcox-designed plants. MIST was sponsored by the US Nuclear Regulatory Commission, the Babcock Wilcox Owners Group, the Electric Power Research Institute, and Babcock Wilcox. The unique features of the Babcock Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral system facilities to address the thermal-hydraulic SBLOCA questions. MIST and two other supporting facilities were specifically designed and constructed for this program, and an existing facility -- the once-through integral system (OTIS) -- was also used. Data from MIST and the other facilities will be used to benchmark the adequacy of system codes, such as RELAP-5 and TRAC, for predicting abnormal plant transients. 7 refs., 321 figs., 14 tabs.

Research Organization:
Nuclear Regulatory Commission, Washington, DC (USA). Div. of Systems Research; Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Babcock and Wilcox Owners Group, Lynchburg, VA (USA); Babcock and Wilcox Co., Lynchburg, VA (USA). Nuclear Power Div.; Babcock and Wilcox Co., Alliance, OH (USA). Research and Development Div.
Sponsoring Organization:
USNRC
OSTI ID:
5492059
Report Number(s):
NUREG/CR-5395-Vol.8; EPRI-NP-6480-Vol.8; BAW-2016; ON: TI90001689; TRN: 89-030966
Resource Relation:
Other Information: This report contains 6 microfiche supplements
Country of Publication:
United States
Language:
English