skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Detection of left ventricular thrombi with radionuclide angiography

Journal Article · · Am. J. Cardiol.; (United States)

Apparent filling defects compatible with left ventricular thrombus are occasionally noted in equilibrium radionuclide angiocardiograms. To define the usefulness of the radionuclide angiogram in detecting left ventricular thrombus, the anterior and left anterior oblique radionuclide angiograms of 39 patients with proved presence or absence of thrombus were blindly interpreted. The presence of thrombus was proved at autopsy in 5 patients, at cardiac operation in 2, or on indium-111 platelet imaging in 6; the absence of thrombus was proved at autopsy in 24 or at cardiac operation in 2. Overall, 13 radionuclide angiograms were interpreted as positive (n . 10) or equivocally positive (n . 3) for thrombus, and 26 studies were judged negative. The sensitivity of a positive or equivocally positive radionuclide angiogram for detection of thrombus was 77 percent (10 of 13 patients), the specificity 88 percent (23 of 26 patients), the positive predictive value 77 percent the negative predictive value 88 percent. If the three equivocal studies are instead considered negative for thrombus, the sensitivity was 62 percent, the specificity 92 percent, the positive predictive value 80 percent and the negative predictive value 93 percent. All thrombi were visualized in the anterior view in an area of akinetic or dyskinetic wall motion. A small group of 13 patients (8 with thrombus, 5 without) underwent two dimensional echocardiography, which was 100 percent sensitive and specific. The finding of a discrete filling defect or squared or cutoff ventricular apex in an area of abnormal wall motion in the anterior view of the radionuclide angiogram should suggest the diagnosis of ventricular thrombus, which may be confirmed by other noninvasive studies.

OSTI ID:
5442731
Journal Information:
Am. J. Cardiol.; (United States), Vol. 48:3
Country of Publication:
United States
Language:
English

Similar Records

Left ventricular thrombi: in vivo detection by indium-111 platelet imaging and two dimensional echocardiography
Journal Article · Wed Apr 01 00:00:00 EST 1981 · Am. J. Cardiol.; (United States) · OSTI ID:5442731

Diagnostic accuracy of indium-111 platelet scintigraphy in identifying left ventricular thrombi
Journal Article · Wed Jun 01 00:00:00 EDT 1983 · Am. J. Cardiol.; (United States) · OSTI ID:5442731

Reliability of gated heart scintigrams for detection of left-ventricular aneurysm: concise communication
Journal Article · Sun Jul 01 00:00:00 EDT 1979 · J. Nucl. Med.; (United States) · OSTI ID:5442731