Active control of a balanced two-stage pendulum vibration isolation system and its application to laser interferometric gravity wave detectors
Journal Article
·
· Review of Scientific Instruments; (United States)
- Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom)
The investigation of the servo control of the position of the bottom mass in a balanced two-stage pendulum vibration isolation system is reported. Experimental results for a simple prototype system and predictions based on a model presented in this paper are in good agreement. The application of such a system to a high-sensitivity laser interferometric gravity wave detector is discussed.
- OSTI ID:
- 5408891
- Journal Information:
- Review of Scientific Instruments; (United States), Vol. 64:5; ISSN 0034-6748
- Country of Publication:
- United States
- Language:
- English