Title: Radioisotope dilution technique for determination of vitamin B/sub 12/ in foods

Journal Article · · J. Assoc. Off. Anal. Chem.; (United States)
OSTI ID:5402470

A radioisotope dilution (RID) method for the determination of vitamin B/sub 12/ is presented. The method combines a standard extraction procedure (AOAC 43.108, 12th ed.) with a commercially available RID assay kit. The method was evaluated on a wide range of fortified and unfortified food products. Recovery studies on both groups yielded average recoveries of 98.1 and 95.8%, respectively. Reproducibility data generated from replicate analysis on both groups gave a relative standard deviation of 6.9% for the fortified group and 9.2% for the unfortified group. For the samples studied, the mean vitamin B/sub 12/ content determined by the RID method was 8.01 ..mu../100 g vs a mean of 7.54 ..mu..g/100 g by the AOAC microbiological method; the correlation coefficient was r = 0.983.

Research Organization:
General Mills, Minneapolis, MN
OSTI ID:
5402470
Journal Information:
J. Assoc. Off. Anal. Chem.; (United States), Vol. 65:1
Country of Publication:
United States
Language:
English