skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Irreversible refrigerators under per-unit-time coefficient of performance optimization

Journal Article · · Applied Physics Letters
DOI:https://doi.org/10.1063/1.120437· OSTI ID:538380
; ; ;  [1]
  1. Departamento de Fisica Aplicada, Facultad de Ciencias, Universidad de Salamanca, 37008 Salamanca (Spain)

A finite-time thermodynamics analysis is used to investigate the optimal coefficient of performance (COP) of an irreversible Carnot refrigerator using the per-unit-time COP as an objective function for optimization. The model includes finite-rate heat transfers between the refrigerant and the external heat reservoirs, heat leak between heat reservoirs, and internal dissipations of the refrigerant. Heat conductances associated with heat transfers are optimized by maximizing the cooling power per unit of capital invested in the refrigerator. The obtained results are consistent with performance data for real low-temperature refrigerators. {copyright} {ital 1997 American Institute of Physics.}

OSTI ID:
538380
Journal Information:
Applied Physics Letters, Vol. 71, Issue 8; Other Information: PBD: Aug 1997
Country of Publication:
United States
Language:
English

Similar Records

New Performance Bounds for a Finite-Time Carnot Refrigerator
Journal Article · Tue Apr 01 00:00:00 EST 1997 · Physical Review Letters · OSTI ID:538380

Optimization and thermodynamic performance measures for a class of finite time thermodynamic cycles
Miscellaneous · Mon Jan 01 00:00:00 EST 1990 · OSTI ID:538380

Specific power optimization for Carnot combined power plants
Journal Article · Tue Dec 31 00:00:00 EST 1996 · International Journal of Energy-Environment-Economics · OSTI ID:538380