Abstract

Ozone and total oxidant concentrations in a rural atmosphere in Western Maryland were measured for the 2-week period 26 August to 9 September, 1980. Unusually high values for ozone, measured by a chemiluminescence method, and for total oxidant, measured by a colorimetric technique, were observed during both daylight and darkness. The 14-day average diurnal curve showed a minimum of 0.04 ppM ozone at 0845 EST, and a broad maximum of 0.075 ppM ozone at 1300 to 1830 EST. A maximum 15-minute average concentration of 0.13 ppM was measured. The average ozone concentration for the entire 14-day period was 0.059 ppM, while the total oxidant concentration was 0.060 ppM.

Authors:
;
Publication Date:
Research Org.:
Research Triangle Inst., Research Triangle Park, NC (USA)
OSTI Identifier:
5381140
Resource Type:
Book
Country of Publication:
United States
Language:
English
Subject:
54 ENVIRONMENTAL SCIENCES; OZONE; CONCENTRATION RATIO; AIR POLLUTION MONITORS; CHEMILUMINESCENCE; EXPERIMENTAL DATA; MARYLAND; OZONIZATION; CHEMICAL REACTIONS; DATA; FEDERAL REGION III; INFORMATION; LUMINESCENCE; MEASURING INSTRUMENTS; MONITORS; NORTH AMERICA; NUMERICAL DATA; USA; 500200* - Environment, Atmospheric- Chemicals Monitoring & Transport- (-1989)

Citation Formats

Richter, H G, and Helms, Jr, G T. Recent ozone episode over western Maryland. United States: N. p., 1980. Web.
Richter, H G, & Helms, Jr, G T. Recent ozone episode over western Maryland. United States.
Richter, H G, and Helms, Jr, G T. 1980. "Recent ozone episode over western Maryland". United States.
@article{osti_5381140,
title = {Recent ozone episode over western Maryland},
author = {Richter, H G and Helms, Jr, G T},
abstractNote = {Ozone and total oxidant concentrations in a rural atmosphere in Western Maryland were measured for the 2-week period 26 August to 9 September, 1980. Unusually high values for ozone, measured by a chemiluminescence method, and for total oxidant, measured by a colorimetric technique, were observed during both daylight and darkness. The 14-day average diurnal curve showed a minimum of 0.04 ppM ozone at 0845 EST, and a broad maximum of 0.075 ppM ozone at 1300 to 1830 EST. A maximum 15-minute average concentration of 0.13 ppM was measured. The average ozone concentration for the entire 14-day period was 0.059 ppM, while the total oxidant concentration was 0.060 ppM.},
doi = {},
url = {https://www.osti.gov/biblio/5381140}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Jan 01 00:00:00 EST 1980},
month = {Tue Jan 01 00:00:00 EST 1980}
}

Book:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this book.

Save / Share: