Installation restoration program. Final remedial investigation report. Volume I. 120th Fighter Wing, Montana Air National Guard, Great Falls International Airport, Great Falls, Montana. Final report
A Remedial Investigation was conducted at the Great Falls Air National Guard Base during April, May, and July 1996. During the period four IRP sites were investigated (IRP Sites 1, 6, 7, and 8). The investigation consisted of drilling 14 soil borings and installing 10 monitoring wells. At Sites 1 and 6, no contaminants in the soil or groundwater were found above State and Federal cleanup levels; and a Decision Document to support no further action is recommended. At Sites 7 and 8, no contaminants were found in the soil above State and Federal cleanup levels; and a Decision Document to support no further action with respect to soil contamination is recommended. At Sites 7 and 8, groundwater contamination above State and Federal cleanup levels was detected. The contamination included petroleum hydrocarbons, chlorinated solvents, and dissolved metals. It is recommended that an Engineering Evaluation/Cost Analysis be prepared to evaluate remedial alternatives for the groundwater at Sites 7 and 8.
- Research Organization:
- Lockheed Martin Energy Systems, Inc., Oak Ridge, TN (United States)
- OSTI ID:
- 529791
- Report Number(s):
- AD-A-326611/1/XAB; CNN: Contract DE-AC05-84OR21400; TRN: 72650160
- Resource Relation:
- Other Information: PBD: May 1997
- Country of Publication:
- United States
- Language:
- English
Similar Records
Installation restoration program. Final remedial investigation report. Volume II. Appendix A-L: 120th Fighter Wing, Montana Air National Guard, Great Falls International Airport, Great Falls, Montana. Final report
Installation restoration program. Site investigation report for IRP site No. 12 and 13, South Dakota Air National Guard, 114th Fighter Wing, Joe Foss Field, Sioux Falls, South Dakota - Volume 1. Final report