skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Hydraulic model studies on bulb turbine intakes. Technical report

Technical Report ·
OSTI ID:5282058

Intakes for bulb and rim generator turbines are very large in relation to their runner diameters. Because the water velocity is low in the intake area, the losses are small. This report describes research on the effect that simplifying the intake design has on energy losses and flow distribution. Using straight surfaces in place of curved bellmouth entrances and shortening the length of the intake could significantly reduce construction costs. In addition, reducing the intake size would reduce the size of trashracks, gates, and associated operating equipment.

Research Organization:
Bureau of Reclamation, Denver, CO (USA). Engineering and Research Center
OSTI ID:
5282058
Report Number(s):
PB-83-251751; REC-ERC-82-14
Country of Publication:
United States
Language:
English