Coil performances of superconducting cables for ac applications
- GEC Alsthom, DEA, 3 avenue des Truis Chenes, 90018 Belfort (FR)
- Alcatel Alsthom Recherche, Route de Nozay, 91460 Marcoussis (FR)
- EDF-DER, 1 avenue du General de Gaulle, 92141 Clamart (FR)
Multifilamentary superconducting wires with a greatly reduced level of losses have been produced with unit lengths of several tens of kilometers. The authors manufactured three industrial wires named L, T, and S, comprising respectively 377982, 597102 and 920304 filaments, 0.14 {mu}m in diameter with a 0.13 {mu}m spacing between filaments. The characteristics of these wires are already published and the authors have tested coils made with (6 + 1) cables of each kind of strands (L, T, and S), the results are also published in A.S.C.90. In this paper, the results of coil tests performed with a (6 + 1) of L strand from 0 to 100 Hz are given, as well as the first results of the tests of coils made with two stage cables (6 + 1){sup 2} with L, T and S strands.
- OSTI ID:
- 5258836
- Report Number(s):
- CONF-910662-; CODEN: IEMGA
- Journal Information:
- IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States), Vol. 28:1; Conference: 12. international conference on magnet technology, Leningrad (USSR), 23-28 Jun 1991; ISSN 0018-9464
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of new Nb-Ti wires with a Cu-Si alloy matrix for AC use
Dependence of self field AC losses in AC multifilamentary composites and cables on external AC magnetic field
Related Subjects
SUPERCONDUCTIVITY AND SUPERFLUIDITY
24 POWER TRANSMISSION AND DISTRIBUTION
AC SYSTEMS
SUPERCONDUCTING CABLES
SUPERCONDUCTING COILS
PERFORMANCE
DESIGN
FABRICATION
SUPERCONDUCTING WIRES
CABLES
CONDUCTOR DEVICES
ELECTRIC CABLES
ELECTRICAL EQUIPMENT
EQUIPMENT
POWER SYSTEMS
WIRES
665412* - Superconducting Devices- (1992-)
240302 - Power Transmission Lines & Cables- Superconducting Cables- (1990-)