Title: Feedwater cleanup for combined electrolysis catalytic exchange. Final report

Technical Report ·
OSTI ID:5258236

Chemical analyses were performed on a series of samples of tritiated wastewater from the Mound Effluent Recovery System (ERS). These analyses indicated that a wide range of organic impurities, as well as several specific inorganic impurities, was present in the water. One of the more damaging organic contaminants found was oil; therefore laboratory experiments were conducted to develop an oil removal method. Based on results of these analyses and experiments, a pilot scale system was designed and built to remove impurities from Mound ERS water. This system successfully removed impurities from ERS water making it suitable as feed for the combined Electrolysis Catalytic Exchange (CECE) system.

Research Organization:
Mound Facility, Miamisburg, OH (USA)
DOE Contract Number:
AC04-76DP00053
OSTI ID:
5258236
Report Number(s):
MLM-2970; ON: DE82019848
Country of Publication:
United States
Language:
English