skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Dosimetry of a silicone breast prosthesis

Journal Article · · Radiology; (United States)

Dose measurements were conducted in a phantom which simulates breast tissue and in another phantom which simulates a breast containing a silicone prosthesis. No detectable difference was found when the irradiations were carried out with tangential beams of /sup 60/Co radiation. The degree of backscatter and absorption of radiation by the prosthesis and phantom were also similar. A slight decrease in dose of approximately 8% was found at the interface between the prosthesis and muscle-equivalent material.

Research Organization:
Hospital for Sick Children, Toronto, Canada
OSTI ID:
5217226
Journal Information:
Radiology; (United States), Vol. 135:1
Country of Publication:
United States
Language:
English

Similar Records

Electron beam irradiation after reconstruction with silicone gel implant in breast cancer
Journal Article · Sun Jun 01 00:00:00 EDT 1986 · Am. J. Clin. Oncol.; (United States) · OSTI ID:5217226

Effect of silicone gel breast prosthesis on electron and photon dose distributions
Journal Article · · Med. Phys.; (United States) · OSTI ID:5217226

Effect of silicone gel breast prosthesis on electron and photon dose distributions
Journal Article · Sat Jan 01 00:00:00 EST 1983 · Med. Phys.; (United States) · OSTI ID:5217226