Title: Column chromatographic preconcentration of copper in alloys and complex materials using 9,10 phenanthrenequinone monoxime supported on naphthalene

Journal Article · · Analytical Letters; (United States)
;  [1]
  1. Indian Inst. of Tech., New Delhi (India)

A solid chelating compound phenanthrenequinone monoxime (PQM) supported on naphthalene provides a rapid and economical means of preconcentration and separation of copper from the aqueous samples. Copper forms a complex with PQM supported on naphthalene in the column at pH 6.1-8.4 with a flow rate of 1 ml/min. The metal complex and naphthalene are dissolved out from the column with 5 ml of DMP and the absorbance is measured at 470 nm against reagent blank. Beer's law is obeyed in the concentration range 0.6-9.6 {mu}g of copper in 5 ml of DMF. The molar absorptivity and sensitivity are 6.3 {times} 10{sup 4} L mol{sup {minus} 1} cm{sup {minus} 1} and 0.001 {mu}g cm{sup {minus} 2} respectively.

OSTI ID:
5185798
Journal Information:
Analytical Letters; (United States), Vol. 25:3; ISSN 0003-2719
Country of Publication:
United States
Language:
English