Cathodic protection design using the regression and correlation method
Conference
·
OSTI ID:512030
- Petroquimica de Venezuela, S.A., Maracaibo (Venezuela)
- INELECTRA, Caracas (Venezuela)
A computerized statistical method which calculates the current demand requirement based on potential measurements for cathodic protection systems is introduced. The method uses the regression and correlation analysis of statistical measurements of current and potentials of the piping network. This approach involves four steps: field potential measurements, statistical determination of the current required to achieve full protection, installation of more cathodic protection capacity with distributed anodes around the plant and examination of the protection potentials. The procedure is described and recommendations for the improvement of the existing and new cathodic protection systems are given.
- OSTI ID:
- 512030
- Report Number(s):
- CONF-970332-; TRN: IM9736%%156
- Resource Relation:
- Conference: Corrosion 97. 52. annual corrosion conference of the National Association of Corrosion Engineers: economics and performance - bridging the gap and NACExpo, New Orleans, LA (United States), 9-14 Mar 1997; Other Information: PBD: 1997; Related Information: Is Part Of Corrosion/97 conference papers; PB: [4584] p.
- Country of Publication:
- United States
- Language:
- English
Similar Records
Galvanic anode cathodic polarization of steel in seawater. Part 3: Retrofit cathodic protection of offshore structures
Predictive maintenance program of cathodic protection systems in a petrochemical complex
Twin anode ribbons cathodically protect Alyeska line
Journal Article
·
Tue Jun 01 00:00:00 EDT 1999
· Corrosion
·
OSTI ID:512030
Predictive maintenance program of cathodic protection systems in a petrochemical complex
Conference
·
Mon Sep 01 00:00:00 EDT 1997
·
OSTI ID:512030
Twin anode ribbons cathodically protect Alyeska line
Journal Article
·
Tue Mar 01 00:00:00 EST 1977
· Pipeline News; (United States)
·
OSTI ID:512030