skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Health hazard evaluation report HETA 83-369-1672, Lockheed-Georgia Company, Marietta, Georgia

Technical Report ·
OSTI ID:5101310

Working conditions were evaluated in Building 84, at the Lockheed/Georgia Company, Marietta, Georgia where parts removed from C54 aircraft wings were spray-cleaned with 1,1,1-trichloroethane or a solvent blend called Turco T-1000. An authorized representative of the Aeronautical Machinists and Aerospace Workers, Lodge 709, had requested the evaluation to investigate health hazards in Building 84. Air samples taken near an exhaust-ventilation booth were analyzed for solvents. Personal air sampling detected exposures at concentrations well below NIOSH evaluation criteria: 23 parts per million (ppm) 1,1,1-trichloroethane, 350ppm limit; 5.8ppm methylene-chloride, 75ppm limit; 2.8ppm tetrachloroethylene, 50ppm limit; 1.2ppm aromatic hydrocarbons, 25ppm limit; 0.2ppm diacetone-alcohol, 50ppm limit; 0.5ppm n-butanol, 50ppm limit; and 0.2ppm xylene, 100ppm limit. Blood carboxyhemoglobin, total urinary trichloro compounds and m-methyl-hippuric-acid were within or below normal levels. The authors conclude that no solvent exposures above NIOSH recommended levels were detected during the evaluation.

Research Organization:
National Inst. for Occupational Safety and Health, Cincinnati, OH (USA)
OSTI ID:
5101310
Report Number(s):
PB-86-223989/XAB; HETA-83-369-1672
Country of Publication:
United States
Language:
English