Title: Portable monitor for the determination of reactor coolant surface radionuclide activities. [PWR; BWR]

Technical Report ·
OSTI ID:5062829

The determination of primary surface deposited radionuclide activities has, in the past, been severely limited by physical structures and equipment size. In order to simplify the acquisition of this in-plant data, a portable gamma spectroscopy system has been assembled. This system consists of a planar high purity germanium (HpGe) detector mounted in a Multi-use Portable Spectrometer (MPS) cryostat purchased from Princeton Gamma-Tech and an ND-Six portable multichannel analyzer (MCA) purchased from Nuclear Data, Inc. Weighing less than 30 pounds, the entire system is completely battery powered and allows storage of accumulated spectra on mini-cassettes. Shielding and collimation is provided by a tungsten-based alloy obtained from Teledyne Power Alloys. The analytical methodology necessary for determining pipewall surface activities and manway insert activities has also been developed.

Research Organization:
Westinghouse Electric Corp., Monroeville, PA (USA). Nuclear Center
OSTI ID:
5062829
Report Number(s):
EPRI-NP-2523; ON: DE82905825; TRN: 82-018560
Country of Publication:
United States
Language:
English