Title: Indicated and actual mass inventory measurements for an inverted U-tube steam generator

Abstract

Results from an experimental investigation of actual versus indicated secondary liquid level in a steam generator at steaming conditions are presented. The experimental investigation was performed in two different small scale U-tube-in-shell steam generators at typical pressurized water reactor operating conditions (5-7 MPa; saturated) in the Semiscale facility. During steaming conditions, the indicated secondary liquid level was found to vary considerably from the actual ''bottled-up'' liquid level. These difference between indicated and actual liquid level are related to the frictional pressure drop associated with the two-phase steaming condition in the riser. Data from a series of bottle-up experiments (Simultaneously, the primary heat source and secondary feed and steam are terminated) are tabulated and the actual liquid level is correlated to the indicated liquid level.

Authors:
; ;
Publication Date:
Research Org.:
EG and G Idaho, Inc., Idaho Falls (USA)
OSTI Identifier:
5052110
Report Number(s):
EGG-M-06986; CONF-861211-5
ON: DE86013481
DOE Contract Number:  
AC07-76ID01570
Resource Type:
Conference
Resource Relation:
Conference: American Society of Mechanical Engineers winter meeting, Anaheim, CA, USA, 7 Dec 1986; Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; PWR TYPE REACTORS; STEAM GENERATORS; TESTING; CORRELATIONS; FLUID FLOW; LEVELS; BOILERS; REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; 210200* - Power Reactors, Nonbreeding, Light-Water Moderated, Nonboiling Water Cooled

Citation Formats

Loomis, G G, Plessinger, M P, and Boucher, T J. Indicated and actual mass inventory measurements for an inverted U-tube steam generator. United States: N. p., 1986. Web.
Loomis, G G, Plessinger, M P, & Boucher, T J. Indicated and actual mass inventory measurements for an inverted U-tube steam generator. United States.
Loomis, G G, Plessinger, M P, and Boucher, T J. 1986. "Indicated and actual mass inventory measurements for an inverted U-tube steam generator". United States.
@article{osti_5052110,
title = {Indicated and actual mass inventory measurements for an inverted U-tube steam generator},
author = {Loomis, G G and Plessinger, M P and Boucher, T J},
abstractNote = {Results from an experimental investigation of actual versus indicated secondary liquid level in a steam generator at steaming conditions are presented. The experimental investigation was performed in two different small scale U-tube-in-shell steam generators at typical pressurized water reactor operating conditions (5-7 MPa; saturated) in the Semiscale facility. During steaming conditions, the indicated secondary liquid level was found to vary considerably from the actual ''bottled-up'' liquid level. These difference between indicated and actual liquid level are related to the frictional pressure drop associated with the two-phase steaming condition in the riser. Data from a series of bottle-up experiments (Simultaneously, the primary heat source and secondary feed and steam are terminated) are tabulated and the actual liquid level is correlated to the indicated liquid level.},
doi = {},
url = {https://www.osti.gov/biblio/5052110}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Jan 01 00:00:00 EST 1986},
month = {Wed Jan 01 00:00:00 EST 1986}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: