Title: Development and application of a thermal desorption-based method for the determination of nicotine in inddor environments

Conference ·
OSTI ID:5003167

A personal monitoring system for the determination of exposure to nicotine has been developed. The system consists of a sampling cartidge packed with 200 mg of Tenax GC/sup R/ and a small, constant flow, personal sampling pump. After sampling, the cartridges are analyzed by triethylamine-assisted thermal desorption gas chromatography with nitrogen-selective detection. Collection and desorption efficiencies for the cartridges have been determined. The system has been applied in a variety of work sites, and in 36 restaurants, where measured concentrations of nicotine ranged from 0.5 to 37.2 ..mu..gm/sup /minus/3/. 25 refs., 2 figs., 4 tabs.

Research Organization:
Oak Ridge National Lab., TN (USA)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
5003167
Report Number(s):
CONF-8806120-1; ON: DE88009700
Resource Relation:
Conference: International conference on indoor and ambient air quality, London, UK, 13 Jun 1988