skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Brain imaging: Reduced sensitivity of RARE-derived techniques to susceptibility effects

Journal Article · · Journal of Computer Assisted Tomography
; ; ;  [1]
  1. Westfalian Wilhelms-Univ. Muenster, Muenster (Germany)

Our goal was to evaluate the decreased sensitivity of RARE-derived pulse sequences to susceptibility effects. A variety of RARE-derived T2-weighted fast SE echo (FSE) sequences with echo trains from 6 to 16 were compared with conventional SE (CSE) sequences by means of MRI in phantoms (iron oxides), volunteers (n = 10), and patients (n = 13) with old hemorrhagic brain lesions. All experiments were performed on a 1.5 T clinical MR system (Magnetom SP 4000; Siemens AG, Erlangen, Germany) with constant imaging parameters. Contrast-to-noise ratios (CNRs) of tubes doped with iron oxides at different concentrations and brain areas with physiological iron deposition (red nucleus, substantia nigra) were calculated for CSE and FSE pulse sequences. Areas of old brain hemorrhage were analyzed for lesion conspicuity by blinded analysis with CSE as an internal standard. CNR of iron oxide tubes (TE 90 ins, CSE 45.0 {+-} 3.5, FSE 16 echo trains 28.5 {+-} 3. 1; p {le} 0.01) and iron-containing brain areas decreased with increasing echo trains of FSE sequences. A significantly lower number of old hemorrhagic brain lesions was visible in patients scanned with FSE sequences (6 echo trains: n = 28; 16 echo trains: n = 26) than CSE (n = 40). Our results demonstrate that the sensitivity of RARE-derived techniques to susceptibility effects is significantly decreased compared with CSE. CSE sequences or GE sequences should still be preferred in patients with a history of seizures or intracranial hemorrhage. 25 refs., 3 figs., 1 tabs.

OSTI ID:
437576
Journal Information:
Journal of Computer Assisted Tomography, Vol. 20, Issue 2; Other Information: PBD: Mar-Apr 1996
Country of Publication:
United States
Language:
English

Similar Records

Stroke, evolution of NMR imaging characteristics
Conference · Sun Jan 01 00:00:00 EST 1984 · J. Nucl. Med.; (United States) · OSTI ID:437576

SU-F-J-163: In Vivo Quantification of Sequence Parameter Effect On Geometric Distortion Caused by Implanted Titanium Brachytherapy Applicator
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:437576

NMR characterization of pituitary tumors
Conference · Sun Jan 01 00:00:00 EST 1984 · J. Nucl. Med.; (United States) · OSTI ID:437576