Title: Detection of two-dimensional respiratory movement and its correction on the scintillation camera images (in Japanese)

Journal Article · · Nippon Igaku Hoshasen Gakkai Zasshi, v. 33, no. 8, pp. 671-682
OSTI ID:4337413

Processing of images obtained with a scintillation camera by the on-line computer was described for correction of image distortion due to the respiratory movement. Serial image data sampling and calculation of the center of gravity for each frame allowed the detection of two-dimensional respiratory movement and correction of respiratory movement by superimposition of the frames according to each center of gravity. Experiments with liver phantom and respiration simulator showed that the optimum sampling interval was one-fourth of the respiration cycle in conjunction with siatistical fluctuation in calculation of the center of gravity and precise decision of magnitude of respiratory movement. Results of the calculation well agreed with the actual movement of the phantom. The superimposed images in phantom and patients also well agreed with the static images without respiratory movement. The serial calculations of center of gravity were applied to the verticaliy divided sub-images and possibility of correction was suggested in such a case that the magriiude of movement was not even throughout the organ. In the liver image, the horizontal movement falled to be differentiated from the statistical fluctuation. The correction was not only useful for increased detectability of small lesion but also essential for computer image restoration as a pre-processing. (auth)

Research Organization:
National Inst. of Radiological Sciences, Chiba, Japan
NSA Number:
NSA-29-027175
OSTI ID:
4337413
Journal Information:
Nippon Igaku Hoshasen Gakkai Zasshi, v. 33, no. 8, pp. 671-682, Other Information: Orig. Receipt Date: 30-JUN-74; Bib. Info. Source: JA (JA)
Country of Publication:
Japan
Language:
Japanese

Similar Records

Correction of image distortion in the liver scintigram due to the respiratory movement using an on-line computer system
Journal Article · Wed Nov 01 00:00:00 EST 1972 · Nippon Igaku Hoshasen Gakkai Zasshi, v. 32, no. 8, pp. 653-666 · OSTI ID:4337413

TH-EF-207A-01: Respiratory Motion Correction in 4D-Multi Pinhole Small Animal SPECT
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:4337413

Local respiratory motion correction for PET/CT imaging: Application to lung cancer
Journal Article · Thu Oct 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:4337413