Title: Pressure drop measurements of prototype NET and CEA cable-in-conduit conductors (CICCs)

Conference ·
OSTI ID:426003
; ;  [1]
  1. Florida State Univ., Tallahassee, FL (United States)

The pressure drop of two prototype cable-in-conduit conductors (CICCs) were measured. The NET conductor is a conventional type CICC, while the CEA conductor has a central flow channel to reduce hydraulic impedance. The pressure drop measurements were conducted with helium at temperatures ranging from 2K to 4.7K, and pressure from the saturated vapor pressure to in excess of 3 bar. Computer image analysis was used to estimate the flow cross sectional area and wetted perimeter of the conductors. The data are expressed in terms of a classical friction factor, and compared with precious experimental results.

OSTI ID:
426003
Report Number(s):
CONF-9505186-; TRN: 96:005768-0046
Resource Relation:
Conference: 2. physical phenomena at high magnetic fields conference, Tallahassee, FL (United States), 6-9 May 1995; Other Information: PBD: 1996; Related Information: Is Part Of Proceedings of the physical phenomena at high magnetic fields - II; Fisk, Z.; Gor`kov, L.; Meltzer, D.; Schrieffer, R. [eds.]; PB: 807 p.
Country of Publication:
United States
Language:
English