Remediation by 2-PHASE {trademark} extraction-A 2-year success story
Abstract
Radian has used the Xerox 2-PHASE{trademark} Extraction technology at several facilities worldwide to remove VOCs and petroleum hydrocarbons from subsurface soils and groundwater. The use of high vacuum with 2-PHASE{trademark} causes greater forces to be applied to the subsurface than do other dual-phase methods. 2-PHASE{trademark} improves dewatering, increases vacuum and groundwater radii of influence, deepens vadose zone development, enhances vapor stripping of soil contamination, improves vaporflow, and expedites remediation timeframes. This paper describes the successful 2-year application of 2-PHASE{trademark} to, remediate soil and several groundwater contamination. Contamination occurred under a floor slab near a former solvent spray booth and several underground storage tanks. Contaminants were primarily chlorinated VOCs and mineral spirits ranging to 330 mg/kg in soil and 1,070 mg/L in groundwater. The 2-PHASE{trademark} system was installed in October 1993; business constraints necessitated the completion of remediation within two years. The system was modified and expanded to optimize the removal effectiveness and extend the area of influence. Subsurface soil data obtained 8 and 11 months into the remediation program were used with soil gas data to predict future soil concentrations. VOC concentrations in the soil and groundwater were reduced by over 95 percent, and remediation goals were met within 18more »
- Authors:
-
- Radian Corp. Hernodon, VA (United States)
- Radian, Rochester, NY (United States)
- Xerox Corp., Webster, NY (United States)
- Publication Date:
- OSTI Identifier:
- 425658
- Report Number(s):
- CONF-960527-
TRN: 96:004994-0296
- Resource Type:
- Conference
- Resource Relation:
- Conference: Annual convention of the American Association of Petroleum Geologists, Inc. and the Society for Sedimentary Geology: global exploration and geotechnology, San Diego, CA (United States), 19-22 May 1996; Other Information: PBD: 1996; Related Information: Is Part Of 1996 AAPG annual convention. Volume 5; PB: 231 p.
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 54 ENVIRONMENTAL SCIENCES; SOILS; REMEDIAL ACTION; GROUND WATER; VAPORS; REMOVAL; ORGANIC COMPOUNDS; VOLATILE MATTER
Citation Formats
Koerner, C, Dee, P E, Baxter, J, and Huber, S. Remediation by 2-PHASE {trademark} extraction-A 2-year success story. United States: N. p., 1996.
Web.
Koerner, C, Dee, P E, Baxter, J, & Huber, S. Remediation by 2-PHASE {trademark} extraction-A 2-year success story. United States.
Koerner, C, Dee, P E, Baxter, J, and Huber, S. 1996.
"Remediation by 2-PHASE {trademark} extraction-A 2-year success story". United States.
@article{osti_425658,
title = {Remediation by 2-PHASE {trademark} extraction-A 2-year success story},
author = {Koerner, C and Dee, P E and Baxter, J and Huber, S},
abstractNote = {Radian has used the Xerox 2-PHASE{trademark} Extraction technology at several facilities worldwide to remove VOCs and petroleum hydrocarbons from subsurface soils and groundwater. The use of high vacuum with 2-PHASE{trademark} causes greater forces to be applied to the subsurface than do other dual-phase methods. 2-PHASE{trademark} improves dewatering, increases vacuum and groundwater radii of influence, deepens vadose zone development, enhances vapor stripping of soil contamination, improves vaporflow, and expedites remediation timeframes. This paper describes the successful 2-year application of 2-PHASE{trademark} to, remediate soil and several groundwater contamination. Contamination occurred under a floor slab near a former solvent spray booth and several underground storage tanks. Contaminants were primarily chlorinated VOCs and mineral spirits ranging to 330 mg/kg in soil and 1,070 mg/L in groundwater. The 2-PHASE{trademark} system was installed in October 1993; business constraints necessitated the completion of remediation within two years. The system was modified and expanded to optimize the removal effectiveness and extend the area of influence. Subsurface soil data obtained 8 and 11 months into the remediation program were used with soil gas data to predict future soil concentrations. VOC concentrations in the soil and groundwater were reduced by over 95 percent, and remediation goals were met within 18 months following start of in situ 2-PHASE{trademark} remediation. The system has been decommissioned following agency and landowner approval.},
doi = {},
url = {https://www.osti.gov/biblio/425658},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Dec 31 00:00:00 EST 1996},
month = {Tue Dec 31 00:00:00 EST 1996}
}