Title: Evaluation of the modular inclined screen (MIS) at the Green Island Hydroelectric Project: 1995 test results

Technical Report ·
OSTI ID:418238
; ;  [1]; ; ; ; ;  [2]
  1. Stone and Webster Environmental Technology and Services, Boston, MA (United States)
  2. Worcester Polytechnic Inst., Holden, MA (United States). Alden Research Lab.

The Electric Power Research Institute (EPRI) developed a fish diversion screen, known as the Modular Inclined Screen (MIS), to prevent fish mortality at water intakes. hydraulic model testing and successful biological evaluation of the MIS had been completed in the laboratory. Following discussions with various federal and state agencies, the Green Island hydroelectric Project was selected as the field test location. This project is located on the Hudson River, just north of Albany, in Green Island, New York. The MIS test facility was operated and tested in the fall of 1995. In addition to the MIS, the effectiveness of a strobe light system was studied to determine its ability to divert blueblack herring form the river to the MIS.

Research Organization:
Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Niagara Mohawk Power Corp., Buffalo, NY (United States); California Dept. of Water Resources, Sacramento, CA (United States); New England Power Co., Westborough, MA (United States); Empire State Electric Energy Research Corp., New York, NY (United States); New York State Energy Research and Development Authority, Albany, NY (United States)
Sponsoring Organization:
Electric Power Research Inst., Palo Alto, CA (United States)