- Texas A and M Univ., College Station, TX (United States)
A numerical investigation of laminar forced convective heat transfer was performed in a three-dimensional channel with baffles in which a uniform heat flux was applied to the top and bottom walls, and the sidewalls were considered diabatic. The trade-off between heat transfer enhancement and pressure drop produced by the baffles was studied for periodically fully developed flow (PDF). The numerical analysis was performed using a finite volume approach. The computer code was validated against the experimental results of Goldstein and Kreid and Beavers et al. for a three-dimensional channel without baffles. Parametric runs were made for Reynolds numbers of 150, 250, 350, and 450 for baffle height to channel width ratios (H/D{sub y}) of 0.5, 0.6, 0.7, and 0.8. Heat transfer behavior was studied for Prandtl numbers of 0.7 and 7.0, and for wall thermal conductivity to fluid thermal conductivity ratios (K) of 1, 10, 100, and 1000.
- Sponsoring Organization:
- USDOE
- OSTI ID:
- 417929
- Journal Information:
- Numerical Heat Transfer. Part A, Applications, Vol. 30, Issue 2; Other Information: PBD: 9 Aug 1996
- Country of Publication:
- United States
- Language:
- English
Similar Records
Heat transfer in rectangular channels with a series of normally in-line positioned plates
Heat transfer in 3-D serpentine channels with right-angle turns