skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Cryogenic system for ITER CS model coil

Conference ·
OSTI ID:416706
; ; ;  [1]
  1. JAERI, Naka Fusion Research Establishment, Nada-machi, Nada-gun, Ibaraki-ken (Japan); and others

A 5-kW/4.5-K helium refrigerator has been developed, which will be used for the test of ITER Central Solenoid Model Coil that is under fabrication by an international collaboration under the framework of the ITER Engineering Design Activity. Its acceptance test was recently finished and its specified refrigeration power of 5 kW with a surplus liquefaction rate of 114 1/h was demonstrated. A major feature of the refrigerator is that newly developed components, such as helium compressor and turbo-expander, are adopted in its simple refrigeration process in order that the results will be transferred to the ITER helium cryogenic system.

OSTI ID:
416706
Report Number(s):
CONF-950722-; TRN: 97:001677
Resource Relation:
Conference: CEC/ICMC `95: cryogenic engineering conference and international cryogenic materials conference, Columbus, OH (United States), 17-21 Jul 1995; Other Information: PBD: 1996; Related Information: Is Part Of Advances in cryogenic engineering. Volume 41, Part A & B; Kittel, P. [ed.]; PB: 2037 p.
Country of Publication:
United States
Language:
English

Similar Records

Construction of ITER common test facility for CS model coil
Journal Article · Mon Jul 01 00:00:00 EDT 1996 · IEEE Transactions on Magnetics · OSTI ID:416706

Recommendations for a cryogenic system for ITER (International Thermonuclear Experimental Reactor)
Conference · Wed Sep 20 00:00:00 EDT 1989 · OSTI ID:416706

Cryogenic Test Results of the ITER TF Model Coil Test in TOSKA
Journal Article · Wed Jun 23 00:00:00 EDT 2004 · AIP Conference Proceedings · OSTI ID:416706