Title: 3-D seismic response of buried pipelines laid through fault

Abstract

An ideal model for the non-causative fault is put forward in which the fault is assumed to be composed by three horizontally adjacent soil media. Dynamic behaviors of pipelines laid through the fault is analyzed. Although simple, this model may qualitatively illustrate the accumulation of seismic waves in the fault, so illustrate the dynamic behaviors of the pipelines. The results show that, the fault is materially different from a two soil site even if the fault width is very narrow, and the dynamic behaviors of the pipelines laid through the fault are determined by the fault width, the stiffness ratio of the three soil media, and the type of the seismic waves.

Authors:
 [1]
  1. Tianjin Univ. (China). Dept. of Civil Engineering
Publication Date:
OSTI Identifier:
403437
Report Number(s):
CONF-9508226-
ISBN 0-7844-0101-2; TRN: IM9651%%472
Resource Type:
Conference
Resource Relation:
Conference: 4. U.S. conference on lifeline earthquake engineering, San Francisco, CA (United States), 10-12 Aug 1995; Other Information: PBD: 1995; Related Information: Is Part Of Lifeline earthquake engineering: Proceedings of the fourth U.S. conference; O`Rourke, M.J. [ed.]; PB: 823 p.; Technical Council on Lifeline Earthquake Engineering, Monograph number 6
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING NOT INCLUDED IN OTHER CATEGORIES; PIPELINES; SOIL-STRUCTURE INTERACTIONS; MATHEMATICAL MODELS; THREE-DIMENSIONAL CALCULATIONS; RESPONSE FUNCTIONS; COMPUTERIZED SIMULATION; GEOLOGIC FAULTS; UNDERGROUND FACILITIES

Citation Formats

Liang, J W. 3-D seismic response of buried pipelines laid through fault. United States: N. p., 1995. Web.
Liang, J W. 3-D seismic response of buried pipelines laid through fault. United States.
Liang, J W. 1995. "3-D seismic response of buried pipelines laid through fault". United States.
@article{osti_403437,
title = {3-D seismic response of buried pipelines laid through fault},
author = {Liang, J W},
abstractNote = {An ideal model for the non-causative fault is put forward in which the fault is assumed to be composed by three horizontally adjacent soil media. Dynamic behaviors of pipelines laid through the fault is analyzed. Although simple, this model may qualitatively illustrate the accumulation of seismic waves in the fault, so illustrate the dynamic behaviors of the pipelines. The results show that, the fault is materially different from a two soil site even if the fault width is very narrow, and the dynamic behaviors of the pipelines laid through the fault are determined by the fault width, the stiffness ratio of the three soil media, and the type of the seismic waves.},
doi = {},
url = {https://www.osti.gov/biblio/403437}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Sun Dec 31 00:00:00 EST 1995},
month = {Sun Dec 31 00:00:00 EST 1995}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: